High pressure pump
|
mode of fluids infusion |
Dual Parallel- piston pump |
|
Peak operation pressure |
42Mpa |
|
Flow rate range(set value) |
0.001ml/min~9.999 ml/min |
|
Flow rate accuracy |
RSD<0.06% |
|
Pressure pulsation |
0.1Mpa |
|
Power |
110V / 220V |
UV-Detector
|
Light |
D2 |
|
Wavelength |
190~700nm |
|
Wavelength accuracy |
1nm |
|
Wavelength Precision |
<0.1nm |
|
Noise |
±0.2×10-5AU |
|
Drift |
0.3×10-4AU |
|
Volume (flow cell) |
8μL |
|
Power |
110V / 220V |
Network
Using modern net technology, the
EX1600 connects the LAN port and user’s Intranet with
devices so as to control remotely and share information.
Either in the lab or in the office, or as an enterprise
manager, you can enjoy the experiment process and result
real time; sequentially, achieving remote control,
technical direction, data management and online
maintenance, which greatly improves your work
efficiency.
Intelligent
system
“Online Expert” of the EX1600 help
you to face your daily analyzing works and instrument
maintaining easily, so that you can deal with various
difficulties confidently, reducing the costs of
instrument use.
The advantages of the intelligent
system are monitoring the operations of each instrument
real time, analyzing and potential and existing
failures, providing the solution online and diagnosing
the service life of the instruments and unit components,
so as to replace the parts easily.
Automatic
The EX1600 has achieved the
sub-automatic remote control of the automatization,
which greatly improves the working efficiency of the
instruments.
Their major functions are:
Feeding samples automatically: the
samples can be fed automatically by the precise EX1600
automatic sample feeding system, which restrains the
cross polluting of the samples and improves the
analyzing accuracy..
Verifying the efficiency
automatically: Easy to verify the operation capability
of each unit regularly during installation of IQ/QQ,
manage cybernation functions of other information and
clean poles automatically, which effectively reduces the
flow of substances flow containing salts.
Failures generated during analysis of
an item: Extreme precise sample feeding: For full rope:
RSD<0.3%; for Partial rope: RSD<0.5%; extreme rare
sampling residue: <0.05%; minimizing the sample
pollution caused by the highly absorbing substances.
Extremely quick sample feeding: just
17 seconds; Room temperature that can be refrigerated
for sample feeding
Peltier cooling: temperature can be
down to 4 degree.
Liquid injecting unit and accessories
Parallel pumps
The double pump heads inject liquid
reciprocatedly, which minimizes pulse movement and
prolongs the service life the plunger and sealing ring.
The perfect combination of 1600P pump
and1600SM mixer has created an excellent gradient curve;
In the quaternary gradient system;
the swift and accurate solenoid switching mix the
proportion of flow phases at your will, which improves
the efficiency of the works developed with the user
approach.
Automatic post-cleaning unit: The
different cleaning frequencies can be set according to
the actual salt contents to prevent salt crystal
substances from damaging the plunger or sealing ring.
Solvent tray
The solvent tray can switch flow
phase freely by controlling the switching valve, which
improves the working efficiency greatly. In addition, a
semi-preparation system is optional so that the user can
use the approaches which are developed in the
chromatography analyzing in the segregating and
purifying in the sectors of biology, pharmacy and
chemical.
Detectors
The excellent detecting sensitivity
makes the originally invisible small peak clear;
The service life of the deuterium is
over 2,000 hours and it is more durable and reliable.
The 1600UVⅡ detector that is equipped
with the D2 lamp and W lamp can extend the length of the
inspection wave to 900nm, which covers all analyses of
the ultraviolet radiation and visible light.
Additionally, an RI
detector is optional, which covers the application of
glucide which cannot be detected by UV detector.
|